  keysight technologies pxi multiplexer switch modules m9101a, M9102A, m9103a data sheet
02 | keysight | pxi multiplexer switch modules m9101a, M9102A, m9103a C data sheet overview product description the pxi multiplexer switch modules deliver high-speed signal routing of many different channels to a single point, and are ideal for routing multiple analog signals to a measurement device in automated test environments (ate) or data acquisition systems. these switches can operate in a break-before-make mode, ensuring no two points are connected at the same time, or, when needed, allowing multiple channels to be connected simultaneously. the modules include an isolation switch that connects the closed channels to a module common, which minimizes the capacitive loading and leakage currents in larger multiplexer systems. you can also expand multiplexers by linking the common connections of multiple pxi cards. installation and confguration is fast and easy with standard cable connections or an optional connector block, soft front panels, and keysight technologies, inc. connection expert. in addition, software drivers support the most common programming environments such as visual studio, c, c++, visual basic, matlab, and labview. applications C aerospace and defense C automotive C electronic test C medical C semiconductor features C delivers high-speed signal routing of many different channels to a single point C high-speed, long-life reed relays or higher power armature relays C modules operate in break-before-make mode ensuring only one channel is connected at a time C software drivers support the most common programming environments C optional connector blocks offer reliable measurements from robust, high-pincount interconnects C pxi chassis connector compatibility: cpci (j1), pxi-1 (j1 only), pxie hybrid slot C easy programming and control with soft front panels and keysights command expert customer values C get the performance you need with 500 sec switches or up to 60 w per channel C ensure no two points are connected at the same time C scan many points in a compact space C work in your programming environment of choice and reduce development time C fast and easy module installation and confguration
03 | keysight | pxi multiplexer switch modules m9101a, M9102A, m9103a C data sheet easy setup... test... and maintenance hardware platform compliance the multiplexer switch modules are pxi compliant with a j1 connector and can be used in pxi chassis with cpci (j1), pxi-1 (j1 only), or pxie hybrid slot connectors. the pxi format offers high performance in a small, rugged package. it is an ideal deployment platform for many automated test systems. in addition, a wide array of complementary pxi products are currently available, such as multimeters, waveform generators, local oscillators, digitizers, and rf switch modules. software platform io libraries keysight io libraries suite offers fast and easy instrument connections and now extends to modular instruments. io libraries suite 16 adds support for pxi, helping you display all of the modules in your system, whether they are pxi, pxie, or axie, as well as view information about installed software. in addition, the new version allows you to more easily fnd the right driver and start module soft front panels directly with keysight connection expert. figure 1. multiplexer switch soft front panel drivers keysight provides instrument drivers that work with your choice of software, saving time and preserving software and hardware investments. keysight modular instruments come with ivi-com, ivi-c, and labview software drivers that work in the most popular test and measurement development environments including labview, matlab, labwindows/cvi, visual studio c, c++, c#, vee, and visual basic. with a broad selection of drivers already included, any keysight pxi multiplexer switch can be swapped out, replaced, or upgraded with the latest version, requiring only minimal software adjustments. easy software integration in addition, application code examples are included for labview, labwindows/cvi, visual studio c, c++, c#, visual basic, and matlab, providing switch set-up and basic functionality. these application code examples are easily modifed to quickly integrate the switch module into your measurement system. software applications keysight soft front panels provide easy-to-use instrument communications. the switch graphical user interface guides developers through module setup so users can quickly confgure the switch states. switch control is also possible through the wide selection of instrument program interfaces.
04 | keysight | pxi multiplexer switch modules m9101a, M9102A, m9103a C data sheet specifcations and characteristics specifcation and characteristic summary following is a summary of specifcations and characteristics for the keysight pxi multiplexer switches. more detailed specifcations and characteristics for each module are featured later in this document. multiplexer switch specifcation and characteristic summary multiplexer switches description type # slots channels switch speed ( typical ) max voltage ( typical ) current switch/ carry ( typical ) relay type connectors m9101a high-density multiplexer pxi 1-slot 64 channels 2-wire 1000 sec 1 100 vrms 2 0.5 a/1.0 a reed 200 lfh connector block or cable M9102A high-density multiplexer pxi 1-slot 128 channels 1-wire 1000 sec 1 100 vrms 2 0.5 a/1.0 a reed 200 lfh connector block or cable m9103a high-density multiplexer pxi 1-slot 99 channels 1-wire 4.5 msec 1 100 vrms 2 1.0 a/1.0 a armature 200 lfh connector block or cable 1. contact factory for more information. 2. not for connection to mains.
05 | keysight | pxi multiplexer switch modules m9101a, M9102A, m9103a C data sheet specifcations and characteristics m9101a pxi high-density multiplexer the m9101a high-density, 64-channel multiplexer has been designed to route many different channels to a single point. the relays are capable of switching up to 100 vrms, with up to 20 w of power, and are ideal for routing analog signals to test instruments in automated test environments (ate) or data acqui - sition systems. each channel has a high and a low connection for 2-wire switching, while an isolation switch connects all closed channels to the module common to minimize capacitive loading and leakage currents in large multiplexer confgurations. easily connect the multiplexer with a high-density, 200-pin low force helix (lfh) connector or cable. m9101a specifcations and characteristics general specifcations channels 64 switch type high-density, 2-wire reed max volts 1 100 vrms max current switch/carry 0.5 a/1.0 a switching characteristics, nominal max power 10 w switch speed ( typical ) 2 1000 usec initial path resistance, differential (typical) 800 m connectors 200 lfh connector block or cable bandwidth 5 mhz dc isolation, ch-ch, ch-gnd 25c/40%rh ( typical ) 25c/80%rh ( typical ) 40c/80%rh ( typical ) 1x10 9 1x10 8 1x10 6 thermal offset contact factory relay life, operations 2 low power load ( typical ) rated power load ( typical ) 1x10 9 > 5x10 6 1. not for connection to mains. 2. relay life is defned as path resistance < 1.5 . figure 2. m9101a 64-ch, 2-wire, reed relays figure 3. 200 lfh connector block
06 | keysight | pxi multiplexer switch modules m9101a, M9102A, m9103a C data sheet specifcations and characteristics M9102A pxi high-density multiplexer the M9102A high-density, 128-channel multiplexer features 1-wire, high-speed, long-life reed relays capable of switching up to 100 vrms, with up to 20 w of power. the modules isolation switch connects the closed channels to the module common. create a larger multiplexer by linking the common connections on multiple pxi cards. easily connect the multiplexer with a high-density, 200-pin low force helix (lfh) connector or cable. M9102A specifcations and characteristics general specifcations channels 128 switch type high-density, 1-wire reed max volts 1 100 vrms max current switch/carry 0.5 a/1.0 a switching characteristics, nominal max power 10 w switch speed ( typical ) 1000 usec initial path resistance, single ended ( typical ) 400 m connectors 200 lfh connector block or cable bandwidth 5 mhz dc isolation, ch-ch, ch-gnd 25c/40%rh ( typical ) 25c/0%rh ( typical ) 40c/0%rh ( typical ) 1x10 9 1x10 8 1x10 6 thermal offset contact factory relay life, operations 2 low power load ( typical ) rated power load ( typical ) 1x10 9 > 5x10 6 1. not for connection to mains. 2. relay life is defned as path resistance < 1.5 . figure 4. M9102A 128-ch, 1-wire, reed relays
07 | keysight | pxi multiplexer switch modules m9101a, M9102A, m9103a C data sheet specifcations and characteristics m9103a pxi high-density multiplexer the m9103a is a high-density, 99-channel, high-powered armature relay multiplexer. each channel has a high and low for 2-wire switching and can switch up to 100 vrms, with up to 60 w of power. the modules isolation switch connects the closed channels to the module common. easily connect to the multiplexer with a high-density, 200-pin low force helix (lfh) connector or cable. m9103a specifcations and characteristics general specifcations channels 99 switch type 2-wire armature max volts 1 100 vrms max current switch/carry 1 a switching characteristics, nominal max power 60 w switch speed ( typical ) 4.5 msec initial path resistance, differential ( typical ) 470 m connectors 200 lfh connector block or cable bandwidth 1 mhz dc isolation, ch-ch, ch-gnd 25c/40%rh ( typical ) 25c/80%rh ( typical ) 40c/80%rh ( typical ) 1x10 9 1x10 7 1x10 5 thermal offset, differential ( typical ) 5 v relay life, operations 2 low power load ( typical ) rated power load (typical) > 1x10 7 > 1x10 5 1. not for connection to mains. 2. relay life is defned as path resistance < 1 . figure 5. m9103a 99-ch, 2-wire, em relays
08 | keysight | pxi multiplexer switch modules m9101a, M9102A, m9103a C data sheet general specifcations slot type pxi 1-slot connector type 200 lfh connector block or cable environmental characteristics 1, 2 temperature operating: 0 to 55 c non-operating: C40 to +70 c relative humidity relative humidity: up to 95% r.h. at 40 c, non-condensing, pollution degree 1 emc european emc directive 2004/108/ec C iec/en 61326-1 C cispr pub 11 group 1, class a C as/nzs cispr 11 C ices/nmb-001 canadian ism device ics-001 safety european low voltage directive 2006/95/ec C etl, ul/iec/en 61010-1, 2nd edition altitude under relative humidity altitude: up to 4.6 km (15,000 ft) warm-up time 15 minutes, max 1. samples of this product have been type tested in accordance with the keysight environmental test manual and verifed to be robust against the environmental stresses of storage, transportation, and end-use; those stresses include, but are not limited to temperature, humidity, shock, vibration, altitude, and power line conditions. 2. test methods are aligned with iec 60068-2 and levels are similar to mil-prf-28800f class 3. physical characteristics dimensions C 3u/1-slot pxi/compactpci standard C connector slot compatibility: cpci (j1), pxi-1, pxie hybrid slot C front panel complies with ieee1101.10 certifcation and compliance weight m9101a M9102A m9103a 220 g (0.49 lbs) 220 g (0.49 lbs) 230 g (0.51 lbs) power requirements m9101a M9102A m9103a +3.3 v 0 0 0 +5 v 134 ma (280 ma) ( typ ) 134 ma (280 ma) ( typ ) 300 ma ( typ ) +12 v 0 0 0 specifcations and characteristics
09 | keysight | pxi multiplexer switch modules m9101a, M9102A, m9103a C data sheet specifcations and characteristics system requirements topic windows 7 and vista requirements windows xp requirements operating systems windows 7 (32-bit and 64-bit) windows vista, sp1 and sp2 (32-bit and 64-bit) windows xp, service pack 3 processor speed 1 ghz 32-bit (x86), 1 ghz 64-bit (x64) (no support for itanium 64) 600 mhz or higher required 800 mhz recommended available memory 4 gb minimum 8 gb or greater recommended 3 gb minimum available disk space 1 1.5 gb available hard disk space, includes: C 1 gb available for microsoft .net framework 3.5 sp1 2 C 100 mb for keysight io libraries suite 1.5 gb available hard disk space, includes: C 1 gb available for microsoft .net framework 3.5 sp1 2 C 100 mb for keysight io libraries suite video support for directx 9 graphics with 128 mb graphics memory recommended (super vga graphics is supported) super vga (800 x 600) 256 colors or more browser microsoft internet explorer 7.0 or greater microsoft internet explorer 6.0 or greater 1. because of the installation procedure, less memory may be required for operation than is required for installation. 2. .net framework runtime components are installed by default with windows vista and windows 7. therefore, you may not need this amount of available disk space.
10 | keysight | pxi multiplexer switch modules m9101a, M9102A, m9103a C data sheet software instrument connection software keysight io library keysight io libraries suite offers a single entry point for a connection to modular and traditional instruments. it automatically discovers interfaces, chassis, instruments, and identifes updates to ivi instrument drivers. io libraries suite safely installs in side-by-side mode with ni i/o software. free software www.keysight.com/fnd/iosuite module management keysight connection expert the keysight connection expert is the graphical user interface included in the io libraries suite that allows you to search for, verify and update ivi instrument and soft front panel drivers for modular and traditional instruments. free software included in the io libraries www.keysight.com/fnd/iosuite module setup and usage keysight soft front panel the pxi module includes a soft front panel (sfp), a software-based graphical user interface (gui) which enables the instruments capabilities from your pc. included on cd-rom with module programming drivers development environments lvi-com ivi-c labview visual basic visual studio (vb.net, c#, c/c++) vee labview, labwindows/cvi, matlab included on cd-rom with module programming assitance command expert assists in fnding the right instrument commands and setting correct parameters. a simple interface includes documentation, examples, syntax checking, command execution and debug tools to build sequences for integration in excel, matlab, visual studio, labview, vee, systemvue. free software www.keysight.com/fnd/commandexpert programming examples each module includes programming program examples available for labview, labwindows/cvi, visual studio c, c++, c#, visual basic, and matlab
11 | keysight | pxi multiplexer switch modules m9101a, M9102A, m9103a C data sheet related products model description m9018a 18-slot pxie chassis: 18-slot, 3u, 8 gb/s m9021a pcie ? cable interface: gen 2, x8 m9045b pcie expresscard adaptor: gen 1 y1200b pcie cable: x4 to x8, 2.0 m (used with m9045b) m9048a pcie desktop pc adapter: gen 2, x8 y1202a pcie cable: x8, 2.0 m (used with m9048a) software model description supported operating systems microsoft windows xp (32-bit), microsoft windows vista (32/64-bit) microsoft windows 7 (32/64-bit) standard compliant drivers ivi-com, ivi-c, labview, matlab supported application development environments (ade) visual studio (vb.net, c#, c/c++), labview, labwindows/cvi, matlab keysight io libraries includes: visa libraries, keysight connection expert, io monitor confguration and ordering hardware model description each switch includes: getting started guide, software drivers, and keysight i/o libraries m9101a pxi high-density multiplexer: 64-ch, 2-wire, 100 vrms/1 a, reed relays M9102A pxi high-density multiplexer: 128-ch, 1-wire, 100 vrms/1 a, reed relays m9103a pxi high-density multiplexer: 99-ch, 2-wire, 100 vrms/1 a, armature relays accessories model description y1182a pxi connector block: 200-pin, shielded, male y1189a pxi connector cable: 200-pin, lfh male to four 50 pin dtype female connectors, 1 meter y1190a pxi connector cable: 200-pin, lfh male to four 50 pin dtype female connectors, 2 meter recommended chassis confguration for the ultimate inw speed and fexibility, combine your switches with other pxi modules in the keysight m9018a pxie chassis as follows: C select a pxie system module, pcie cable interface, or embedded controller (the keysight m9021a is recommended) C if an external computer is being used, select an appropriate pc interface card (the keysight m9047a is recommended with an external pc) C select an appropriate cable to connect the computer interface board to the system module (the y1202a is recommended to connect the m9047a and m9021a) C select rack mount and emc fller panel kits as required
12 | keysight | pxi multiplexer switch modules m9101a, M9102A, m9103a C data sheet defnitions for specifcations specifcations describe the warranted performance of calibrated instruments that have been stored for a minimum of 2 hours within the operating temperature range of 0 to 55 c, unless otherwise stated, and after a 45 minute warm-up period. data represented in this document are specifcations unless otherwise noted. characteristics describe product performance that is useful in the application of the product, but that is not covered by the product warranty. characteristics are often referred to as typical or nominal values. C typical describes characteristic performance, which 80% of the instruments will meet when operated over a 20 to 30 c temperature range. typical performance is not warranted. C nominal describes representative performance that is useful in the application of the product when operated over a 20 to 30 c temperature range. nominal performance is not warranted. note: all graphs contain measured data from several units at room temperature unless otherwise noted. warranty and calibration advantage services: calibration and warranty keysight advantage services is committed to your success throughout your equipments lifetime. warranty standard warranty is 3 years r-51b-001-5z return-to-keysight warranty extended to 5 years 1. excludes relay wear-out.
this information is subject to change without notice. ? keysight technologies, 2011 - 2014 published in usa, august 1, 2014 5990-7181en www.keysight.com 13 | keysight | pxi multiplexer switch modules m9101a, M9102A, m9103a C data sheet mykeysight www.keysight.com/find/mykeysight a personalized view into the information most relevant to you. www.axiestandard.org advancedtca ? extensions for instrumentation and test (axie) is an open standard that extends the advancedtca for general purpose and semiconductor test. keysight is a founding member of the axie consortium. atca ? , advancedtca ? , and the atca logo are registered us trademarks of the pci industrial computer manufacturers group. www.lxistandard.org lan extensions for instruments puts the power of ethernet and the web inside your test systems. keysight is a founding member of the lxi consortium. www.pxisa.org pci extensions for instrumentation (pxi) modular instrumentation delivers a rugged, pc-based high-performance measurement and automation system. three-year warranty www.keysight.com/find/threeyearwarranty keysights commitment to superior product quality and lower total cost of ownership. the only test and measurement company with three-year warranty standard on all instruments, worldwide. keysight assurance plans www.keysight.com/find/assuranceplans up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/go/quality keysight technologies, inc. dekra certified iso 9001:2008 quality management system keysight channel partners www.keysight.com/find/channelpartners get the best of both worlds: keysights measurement expertise and product breadth, combined with channel partner convenience. pci-sig ? , pcie ? and the pci express ? are us registered trademarks and/or service marks of pci-sig. www.keysight.com/find/modular www.keysight.com/find/pxi-switch for more information on keysight technologies products, applications or services, please contact your local keysight office. the complete list is available at: www.keysight.com/find/contactus americas canada (877) 894 4414 brazil 55 11 3351 7010 mexico 001 800 254 2440 united states (800) 829 4444 asia pacifc australia 1 800 629 485 china 800 810 0189 hong kong 800 938 693 india 1 800 112 929 japan 0120 (421) 345 korea 080 769 0800 malaysia 1 800 888 848 singapore 1 800 375 8100 taiwan 0800 047 866 other ap countries (65) 6375 8100 europe & middle east austria 0800 001122 belgium 0800 58580 finland 0800 523252 france 0805 980333 germany 0800 6270999 ireland 1800 832700 israel 1 809 343051 italy 800 599100 luxembourg +32 800 58580 netherlands 0800 0233200 russia 8800 5009286 spain 800 000154 sweden 0200 882255 switzerland 0800 805353 opt. 1 (de) opt. 2 (fr) opt. 3 (it) united kingdom 0800 0260637 for other unlisted countries: www.keysight.com/find/contactus (bp-09-23-14)